Related Products

Rishabh Vxx Series Current / Voltage Transducer (TRMS/AVG)

RISHABH Vxx Series Current / Voltage Transducer (TRMS/AVG) 
  • Measuring transducer is used to convert a sine - wave or distorted AC current
  • Meets requirements of International Standard IEC688 for accuracy
  • Option of SMPS supply for wide range of AC / DC supply available

Product Details

RISHABH Vxx Series Current / Voltage Transducer (TRMS/AVG)

The RISH Ducer VXX measuring transducer is used to convert a sine - wave or distorted AC current and AC Voltage into an impressed output signal. The output signal is proportional to the root - mean square value of the input current and Voltage.

AC Current & AC Voltage Transducers series
Rish Ducer VXX Very wide range of product to meet the needs of varied applications.

Current

I11 - Average type, Self Powered. (Class 0.5)
I12 - Average type, Self Powered with dual range input (Class 0.5)
I21 - True RMS. (Class 0.5)
I22 - True RMS, (Class 0.2)

Voltage

V11 - Average type, Self Powered. (Class 0.5)
V21 - True RMS. (Class 0.5)
V22 - True RMS, (Class 0.2)

Unique Features

* State of the art products with SMT : Compact & reliable.

* Well proven technology from Gossen Metrawatt Camille Bauer, Germany / Switzerland.

* Meets requirements of International Standard IEC688 for accuracy

* Insulation level of 3.7kV/4kV.

* Impulse withstand voltage 5 kV.

* Higher load capacity : 750 Ohms at 20 mA.

* True RMS models (I21/V21).

* Self Powered models (I1X/V1X)

* Mounting: DIN rail or Panel mounting. Easy “onsite” conversion.

* Response time < 300 mS standard, < 50mS optional.

* Mounting position : Any

* Electrical isolation between all transducer connections.

* Terminal connection: Electricians delight. Even suitable for multistrand or solid wire connection. Large space for lopping of wires.

* Housing : Polycarbonate, Flammability class V-0 acc to UL94, conforming to V0 grade of UL 94.(Self extinguishing, non drip)

* Accuracy class 0.5 as per IEC 688, (I22 & V22 class 0.2.)

* Output short circuit & open circuit proof.

* Option of SMPS supply for wide range of AC / DC supply available.

* Operating temperature - 10 to +55º C.& Storage temperature - 40 to +70º C.

* Optional dual output (accuracy class 0.5 only)

RISHABH RISH Ducer C11 Phase Angle Transducer (PF) The transducer RISH Ducer C11 measures the phase angle between current and voltage of a single or 3 phase balanced network having a sine...
ISKRA MT 518 Current Transducer (U)MT 518 is intended for measuring and monitoring single-phase electrical power network. Input current is electrically isolated from the system by means o...
RISHABH RISH Trans Programmable Multifunction Transducer (Display, Modbus and Analog Output) On site programmable PT/CT ratios It is possible to program primary of external potential Tra...
RISHABH RISH Ducer F12 Frequency Transducer for Measuring Frequency The RISH Ducer F12 measuring transducer is used for frequency measurement. The output signal is proportional to measure...
RISHABH Con V Current / Voltage Transducer The RISH RISH CON - I is used to measure and convert AC Voltage or Current input into an proportional DC current or voltage output signal. Outpu...