Mirus AutoTrans Lineator Harmonic Mitigation Filters

MIRUS AutoTrans Lineator Harmonic Mitigation Filters 
  • It is a low voltage passive harmonic mitigation
  • The use of 6-pulse Variable Speed Drives and other static power conversion equipment
  • No other device on the market can meet the limits of IEEE STD 519 at an equivalent size, efficiency and cost

Product Details

MIRUS AutoTrans Lineator Harmonic Mitigation Filters

The use of 6-pulse Variable Speed Drives and other static power conversion equipment has grown rapidly in recent years. With this growth has come concern over the level of current harmonics generated by such equipment. Harmonic currents and the voltage distortion these currents create can have devastating effects on a power distribution system and its connected equipment. Present methods of harmonic treatment on low voltage 6-pulse VFD applications where the VFD voltage rating is different from the service voltage, require a special replacement 18-Pulse VFD, or a separate transformer to match the existing 6-Pulse VFD voltage along with tuned passive filters, or expensive active filters.

The innovative AutoTranslineator™ is the best advance in the area of low voltage passive harmonic mitigation available today. No other device on the market can meet the limits of IEEE STD 519 at an equivalent size, efficiency and cost. When the application calls for harmonic treatment for low voltage 6-pulse VFD applications where the VFD voltage rating is different from the service voltage, the AutoTranslineator™ is the only logical choice.

MIRUS Lineator 1Q3 1-Phase to Quasi 3-Phase Harmonic Filter The only passive harmonic filter designed for 3-phase VFD's operating on a 1-phase supply. In remote locations such as farms...
MIRUS Drive 18 Transformers Multiple output auto or isolation transformers ideally suited for reduction of harmonics generated by VFDs or other 3-phase rectifier loads. Drive 12/24™ pr...
MIRUS 5-7 Neutral Current Eliminator 3-phase, 3-wire autotransformers with 30°, 15° or 20° phase shift between input and output. They are connected in series with the supply to variable f...
MIRUS Neutral Current Eliminator (NCE) A 3-phase, low zero sequence impedance autotransformer, which when connected near to and in parallel with the harmonic generating non-linear loads (...
MIRUS Drive 12/24 Transformers Multiple output auto or isolation transformers ideally suited for reduction of harmonics generated by VFDs or other 3-phase rectifier loads. Drive 12/24™...