Related Products

Mirus Lineator AUHF 3-Phase Passive Harmonic Mitigation Filters

MIRUS Lineator AUHF 3-Phase Passive Harmonic Mitigation Filters 
  • Easily applied to input of a single VSD
  • Input current demand distortion < 8% over entire operating range
  • Capable of reducing VSD / VFD harmonics by up to 10 times 

Product Details

MIRUS Lineator AUHF 3-Phase Passive Harmonic Mitigation Filters

An easy to apply, passive filter capable of reducing Variable Speed Drive (VSD) / Variable Frequency Drive (VFD) harmonics by up to 10 times with none of the inherent problems of conventional filters.

Features

• Treats all major harmonics generated by Variable Speed Drives and other 3-phase rectifier loads (5th, 7th, 11th, 13th …)
• Exceeds 18-pulse performance in a smaller footprint, at lower cost and without sacrificing energy efficiency
• Easily applied to input of a single VSD
• No need to phase shift against other VSD’s
• No need for costly harmonic studies
• Will meet IEEE 519 standard for both current and voltage distortion
• Input current demand distortion < 8% over entire operating range
• Power factor 0.98 lagging to 0.95 leading over the normal operating range
• Compatible with engine generators since capacitive reactance is < 15% of rated kVA even under light loads
• Will not resonate with other power system components Will not be overloaded by other line side harmonic sources
• Suppresses overvoltages caused by capacitor switching and other fast changing loads
• Eliminates need for drive isolation transformers, AC line reactors and DC link chokes
• Removal of harmonics improves overall system power factor
• Saves energy by reducing upstream harmonic losses while operating at > 99% efficiency
• Reduces DC bus ripple and increases ride-through capability of the load

MIRUS Drive 24 Transformers Multiple output auto or isolation transformers ideally suited for reduction of harmonics generated by VFDs or other 3-phase rectifier loads. Drive 12/24™ pr...
MIRUS 11-13 Neutral Current Eliminator 3-phase, 3-wire autotransformers with 30°, 15° or 20° phase shift between input and output. They are connected in series with the supply to variable...
MIRUS SOLV Harmonic Analysis Software SOLV™ is a powerful simulation program that will calculate current and voltage distortion levels by simulating the Mirus Lineator™ and Variable Speed...
MIRUS Harmony-2E Isolation Transformers and Auto Transformers HARMONY™ SERIES isolation transformers and autotransformers combine very low zero sequence impedance outputs with phase shift...
MIRUS Drive 18 Transformers Multiple output auto or isolation transformers ideally suited for reduction of harmonics generated by VFDs or other 3-phase rectifier loads. Drive 12/24™ pr...