HIOKI 3290-10 Clamp On AC/DC HiTester All the Functions You Need for Measurement at DC or 1Hz and Up

Choice of three sensors (Example combinations)
3290/3290-10 +9691 : Measure up to 100A
3290/3290-10 +9692 : Measure up to 200A
3290/3290-10 +9693 : Measure up to 2000A

Choice of measurement methods
DC (for battery measurement)
AC+DC RMS (for full-/half-wave rectification measurement)
AC RMS (for current distortion measurement)
PEAK (for peak value measurement) of inrush current, etc.)

Choice of output (Simultaneous output)
Effective value output, frequency output, waveform output

3290-10 Functions
Current integral measurement
(obtain polarity-specific integrated DC values)
Operating time/duty measurement

Measurement method : DC, AC+DC (True RMS), AC (True RMS)

Peak value display : Polarities independently (±peak value of waveform, in DC mode)

Separate AC from DC output : None

Output (terminal 1) : Current waveform or true RMS value (2 V / setting range)

Output (terminal 2) : Current integral value (1 VDC / setting range)

Integral current measurement : ±, +, - integral, average value

Rate measurement : Operating time rate, total measurement time

Timer settings : 99 hr, 59 min. (for repeated up to 20 times)

Data storage : Peak, integral value, operating time rate, or other

Basic accuracy at DC current : 20.00/ 100.0A (using the 9691 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
20.00/ 200.0A (using the 9692 sensor): ±1.3 % rdg. ±0.10 A/ ±0.5 A
200.0/ 2000A (using the 9693 sensor): ±1.8 % rdg. ±1.0 A/ ±5 A

Basic accuracy at AC current
(45 to 66 Hz) 20.00/ 100.0A (using the 9691 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
20.00/ 200.0A (using the 9692 sensor): ±1.3 % rdg. ±0.08 A/ ±0.3 A
200.0/ 2000A (using the 9693 sensor): ±1.3 % rdg. ±0.8 A/ ±3 A

Voltage measurement : None

Frequency measurement : 1.00Hz to 1000Hz, Basic accuracy: ±0.3% rdg. ±1dgt.

Crest factor : 2.5 or later, or rated peak value of sensor

Frequency characteristic : DC, or 1 Hz to 1 kHz (accuracy guaranteed range)

At monitor output: based on the using sensor

Other functions : Selectable of responce time, filter (fc=550 Hz)

Power supply : LR6 (AA) alkaline batteries × 4, Continuous use : 22 hr, or AC adapter 9445-02/-03 (The 3290-10 only: external power supply possible)

Dimensions, mass 155 mm (6.10 in) W × 98 mm (3.86 in) H × 47 mm (1.85 in) D, 545 g (19.2 oz)

Supplied accessories : Carrying strap ×1, LR6 (AA) alkaline batteries × 4

HIOKI 3285 Clamp-On AC/DC HiTester AC/DC current measuring up to 2000 A Analog output for current measuring level, current measuring waveform, or frequency measuring level. The peak hold ...
HIOKI CM4372 AC/DC Clamp Meter is the best-in-class measuring devices incorporating Hioki’s expertise in current sensing technology. The CM4372 is a 600A True RMS clamp meter that features s...
FLUKE 353 True-rms 2000 A Clamp Meters Versatile and rugged tools for applications with high currents Confidently take reliable readings with the True-rms, Fluke 355 and 353 digital cl...
HIOKI 3290 Clamp-On AC/DC HiTester All the Functions You Need for Measurement at DC or 1Hz and Up Choice of three sensors (Example combinations) 3290/3290-10 +9691 : Measure up to 100A ...
FLUKE 321 Clamp Meter The Fluke 321 and 322 are designed to verify the presence of load current, AC voltage and continuity of circuits, switches, fuses and contacts. These small and rugge...