Free Call Australia : 1 800 834 991

Related Products

Hioki 3454-11 Digital Meg-Ohm HiTester

HIOKI 3454-11 Digital Meg-Ohm HiTester 
  • Easy-to-read digital display
  • Live-wire warning
  • Safety system for high voltage measurement

Product Details

HIOKI 3454-11 Digital Meg-Ohm HiTester Revolutionary 3 ranges insulation resistance tester with continuity function all in one

Easy-to-read digital display. Auto-discharge, Live-wire warning, Safety system for high voltage measurement. Sliding cover.

Low resistance (continuity) : 40.00O to 4.000MO, 6 ranges, Basic accuracy: ±3% rdg. ±6 dgt. (Open terminal voltage: 4 to 6V, Short circuit current: 200mA, Response time: 5 s or under)

AC voltage range : 0 to 750V, Accuracy: ±3% rdg. ±6 dgt. (50/60 Hz, Guaranteed at 600V or less), Input impedance: 100kO or more

Other functions : Comparator (MO/ O mode), Data hold (MO/ O mode), Auto-discharge, Live-wire warning, Auto-power save, 1000V output error protection

Display : LCD "4000" dgt. with back lighting

Power supply : R6P(AA) manganese batteries × 4 or LR6(AA) alkaline batteries × 4 Continuous use: [250V, 500V] 24h, [1000V] 14h (Insulation test:8 measurement, with manganese batteries)
Number of measurements: [250V/ 0.25MO] 600times, [500V/ 0.5MO] 500times, [1000V/ 1MO] 300times (Insulation test, with manganese batteries, at 5 s ON, 25 s OFF cycle)

Dimensions, mass : 175mm(6,89in)W × 148mm(5.83in)H × 56mm(2.20in)D, 530g(18.7oz) (including batteries)

Supplied accessories : TEST LEAD L9787 ×1, Instruction Manual ×1, R6P (AA) manganese batteries ×4, Strap ×1

HIOKI 3455 High Voltage Insulation HiTester Maximum 5kV Test Voltage - Up to 5TO of Insulated Resistance Testing Measure insulation of high-voltage equipment (such as transformers, cables...
MEGGER MJ15 and BM15 Insulation Testers 5kV Four test voltages to 5 kV, BM15 battery powered. MJ15 hand cranked and optional battery powered, Voltage range to 600 V indicates auto discha...
MEGGER MIT480 Series Telecoms Insulation and Continuity Testers 75V Live circuit inhibit, 600V CATIV applications, TRMS Voltage measurement, Continuity testing at 200mA down to 0.01O, Ins...
MEGGER 212159, 212359, 212459, 212559 Major Insulation Testers No scale multipliers, Multiple test voltages for spot and step voltage testing, Guard terminal to eliminate surface leakage ...
MEGGER S1-554/2 5 kV Insulation Resistance Tester With High Noise Rejection CAT IV 600 V, Charge current: 5 mA, 4 mA noise rejection and software filtering, Mains or battery powered, Digi...