Free Call Australia : 1 800 834 991

Related Products

Rishabh RISH Trans Programmable Multifunction Transducer (Display, Modbus and Analog Output)

RISHABH RISH Trans Programmable Multifunction Transducer (Display, Modbus and Analog Output) 
  • It is possible to program primary of external potential Transformer (PT)
  • The secondary of external Current Transformer (CT) can be programmed on site
  • The instrument measures distorted waveform up to 15th Harmonic

Product Details

RISHABH RISH Trans Programmable Multifunction Transducer (Display, Modbus and Analog Output)

On site programmable PT/CT ratios
It is possible to program primary of external potential Transformer (PT), primary of external Current Transformer (CT) on site locally via RS232 interface or local display (optional) or remotely via MODBUS (RS485).

User selectable CT Secondary 5A/1A
The secondary of external Current Transformer (CT) can be programmed on site to either 6A to 1A locally via RS232 interface or local display (optional) or remotely via MODBUS (RS485).

User selectable PT Secondary
The secondary of external potential Transformer (PT) can be programmed on locally via RS232 interface or local display (optional) or remotely via MODBUS (RS485)

User selectable 3 phase 3W or 4W
User can program on site the network connection as either 3 Phase 3 Wire or 4 Wire locally via RS232 interface or local display (optional) or remotely via MODBUS (RS485).

True RMS measurement
The instrument measures distorted waveform up to 15th Harmonic.

High brightness 3 line 4 digits LED display (OPTIONAL)
Simultaneous display of 3 Parameters

Fast Analog output response(Less then 500ms)
Analog output responds for step input within 500ms.

Number of parameters measured: more than 28
The instrument measures more than 28 electrical parameters of Phase network.

MODBUS (RS485) Output
The MODBUS output enables the instrument to transmit all the measured parameters over standard MODBUS (RS485).

Configuration of the Instrument via MODBUS
The instrument settings can be configured locally via RS232 interface or local display (optional) or remotely via MODBUS (RS485).
Note: The MODBUS communication parameters can only be set locally via RS232 interface or local display (optional).

Analog Outputs (4 Outputs)
4 Analog outputs can be programmed from a list of input parameters.

Compliance to International Safety standards
Compliance to International Safety standard IEC 61010-1- 2001

RISHABH Vxx Series Current / Voltage Transducer (TRMS/AVG) The RISH Ducer VXX measuring transducer is used to convert a sine - wave or distorted AC current and AC Voltage into an impresse...
RISHABH RISH Ducer E13 Current / Voltage Transducer (3 Channel) The Transducer RISH Ducer E13 is used to convert a 3 sine wave AC Voltage or AC Current (depending on types) into a (load i...
RISHABH RISH Ducer M00 Programmable Multifuntion Transducer (LONbus communication) RISH Ducer M00 is a programmable transducer with a LONWORKS® Interface that simultaneously measures sev...
RISHABH RISH Ducer F11 Frequency Transducer for Measuring Frequency The RISH Ducer F11 measuring transducer is used for frequency measurement. The output signal is proportional to measure...
RISHABH RISH Ducer M30 Programmable Multifunction Transducer RISH Ducer M40 is a programmable transducer with a RS 485 bus interface (MODBUS®).It supervises several variables of an electr...